Pennsylvania Code (Last Updated: April 5, 2016) |
Title 34. LABOR AND INDUSTRY |
PART I. Department of Labor and Industry |
Chapter 7. Elevators, Lifts, Escalators, Dumbwaiters, Hoists andTramways |
SubChapter F. POWER-OPERATED SPECIAL INDUSTRIAL SERVICE ELEVATORS |
Section 7.194. Operation
-
(a) The following methods of operation are permitted:
(1) Double-button control.
(2) Momentary-pressure operation with up-down buttons or switches in the car and up-down buttons or switches, or call buttons, at each landing. It is not required that the operation be selective.
(3) Single automatic operation.
(b) A stop switch shall be provided on or adjacent to the operating panel. Stop switches shall be of the manually opened and closed type and shall be conspicuously marked stop and the operating button or handle shall be of a different color from any other switch in the car. The opening of the switch contacts shall not be solely dependent on springs.
(c) The control system shall be so designed that the direction of travel of the elevator be reversed at any point in the hoistway after stopping the elevator from the stop switch or any other method. No control system shall be used which depends upon completion of maintenance of an electric circuit for the following:
(1) Interruption of the power and application of the electro-mechanical brake at the terminals.
(2) Operation of the car safeties.
(3) Stopping in response to the opening of the emergency stop switch.
(d) Hand-rope operation shall not be used.
(e) The sticking or freezing of any single electrically-operated switch, relay, or contactor or the occurrence of a single accidental ground shall not permit the car to start if any hoistway landing door is open or unlocked, or if any car door or gate is not within two inches of full closure.