Pennsylvania Code (Last Updated: April 5, 2016) |
Title 34. LABOR AND INDUSTRY |
PART I. Department of Labor and Industry |
Chapter 7. Elevators, Lifts, Escalators, Dumbwaiters, Hoists andTramways |
SubChapter C. SIDEWALK ELEVATORS |
Section 7.96. Shaftway enclosures and gates
-
(a) Power-driven sidewalk elevators. Power-driven sidewalk elevators shall conform to the following:
(1) New installations. The shaftways of new power-driven sidewalk elevators or basement lifts, shall be enclosed on three sides, except for necessary openings for machinery. The loading sides of the lower and intermediate landings shall be provided with standard manually-operated gates or freight type doors, constructed and installed in accordance with the requirements for freight elevators; and be equipped with approved type interlocks. The cars of power-driven sidewalk elevators shall have all sides not used as a means of ingress or egress thereto solidly enclosed to a height of at least 6 feet. A car gate and contact shall be provided at the side served by the openings below the sidewalk level. The shaftway door at the basement landing shall be equipped with an emergency key.
(2) Existing installations. The shaftways of existing power-driven sidewalk elevators or basement lifts, shall be enclosed on three sides to a height of at least 6 feet, except for necessary openings for machinery. The loading sides or the lower and intermediate landings shall be provided with standard semiautomatic gates, constructed and installed in accordance with the requirements for freight elevators.
(b) Hand sidewalk elevators. Gates and shaftway enclosures are not required in connection with hand sidewalk elevators or basement lifts, except that semiautomatic gates shall be installed at intermediate landings.