Section 56.21. Minimum exits
-
(a) For buildings with up to and including two stories, a minimum of one exit from each floor kept free from obstructions shall be provided.
(b) For buildings, in excess of two stories in height, a minimum of two exits from each floor kept free from obstructions shall be required. At least 50% of required exits shall be exit discharge doors to the outside, stair towers, or ramps.
(1) Basements used only for storage or mechanical equipment without permanent occupancy shall have a minimum of two exit access paths except that the Department may permit a single exit access for basements of less than 1,000 square feet used only for storage or mechanical equipment without permanent occupancy.
(2) Mezzanine levels shall have a minimum of two exit access paths except that the Department may permit a single exit access from mezzanines less than 1,000 square feet or mezzanines used exclusively for storage or mechanical equipment without a permanent occupancy.