Pennsylvania Code (Last Updated: April 5, 2016) |
Title 25. ENVIRONMENTAL PROTECTION |
PART I. Department of Environmental Protection |
Subpart C. Protection of Natural Resources |
Article III. Air Resources |
Chapter 129. Standards for Sources |
Section 129.308. Compliance determination
-
(a) Not later than 14 days prior to the applicable compliance date under § 129.304(b) or (c), the owner or operator of a glass melting furnace subject to this section, § § 129.301129.307, 129.309 and 129.310 shall install, operate and maintain continuous emissions monitoring systems (CEMS, as defined in § 121.1 (relating to definitions)) for NOx and other monitoring systems to convert data to required reporting units in compliance with Chapter 139, Subchapter C (relating to requirements for source monitoring for stationary sources) and calculate actual emissions using the CEMS data reported to the Department. The owner or operator of a glass melting furnace may install or operate, or both, an alternate NOx emissions monitoring system or method, approved in writing by the Department or appropriate approved local air pollution control agency.
(b) Data invalidated under Chapter 139, Subchapter C, shall be substituted with the following if approved in writing by the Department or appropriate approved local air pollution control agency:
(1) The highest valid 1-hour emission value that occurred under similar source operating conditions during the reporting quarter.
(2) If no valid data were collected during the reporting quarter, one of the following shall be reported to the Department or appropriate approved local air pollution control agency:
(i) The highest valid 1-hour emission value that occurred under similar source operating conditions during the most recent quarter for which valid data were collected.
(ii) The highest valid 1-hour emission value that occurred under similar source operating conditions during an alternative reporting period.
(3) An alternative method of data substitution.
(c) Instead of data substitution, the Department or appropriate approved local air pollution control agency may approve an alternative procedure to quantify NOx emissions and glass production.
(d) The owner or operator of a glass furnace subject to this section shall submit to the Department or the appropriate approved local air pollution control agencies quarterly reports of CEMS monitoring data in pounds of NOx emitted per hour, in a format approved by the Department and in compliance with Chapter 139, Subchapter C, or a format approved by the appropriate approved local air pollution control agencies.
(e) The CEMS or approved monitoring system or method for NOx installed under this section must meet the minimum data availability requirements in Chapter 139, Subchapter C.
The provisions of this § 129.308 adopted June 18, 2010, effective June 19, 2010, 40 Pa.B. 3328.
Notation
The provisions of this § 129.308 issued under section 5(a)(1) of the Air Pollution Control Act (35 P. S. § 4005(a)(1)).
This section cited in 25 Pa. Code § 121.1 (relating to definitions); 25 Pa. Code § 129.301 (relating to purpose); 25 Pa. Code § 129.302 (relating to applicability); 25 Pa. Code § 129.304 (relating to emission requirements); and 25 Pa. Code § 129.310 (relating to recordkeeping).