Table B.  


Latest version.


  • Soil CharacteristicsSlopeRequired Spray Field Area (Ft 2)
    Depth To RockDepth To Water Table3 Bedroom HomeAdditional Area Per Bedroom
    16 to 20 inches 10 to 40 inches ‹=12% 40,000 10,000
    ›12% 80,000 20,000
    ›40 inches‹=12% 15,000 3,750
    ›12% 30,000 7,500
    ›20 inches10 to 20 inches‹=12%20,0005,000
    ›12%40,00010,000
    ›20 inches‹=12%10,0002,500
    ›12%20,0005,000

    Authority

    The provisions of this § 73.16 amended under section 9 of the Pennsylvania Sewage Facilities Act (35 P. S. § 750.9); The Clean Streams Law (35 P. S. § § 691.1—691.1001); and section 1920-A of The Administrative Code of 1929 (71 P. S. § 510-20).

    Source

    The provisions of this § 73.16 adopted January 21, 1983, effective January 22, 1983, 13 Pa.B. 508; amended November 7, 1997, effective November 8, 1997, 27 Pa.B. 5877; corrected November 21, 1997, 27 Pa.B. 6079. Immediately preceding text appears at serial pages (221915) to (221916) and (217317) to (217318).

    Cross References

    This section cited in 25 Pa. Code § 71.52 (relating to content requirements—new land development revisions); 25 Pa. Code § 71.63 (relating to retaining tanks); 25 Pa. Code § 72.22 (relating to permit issue); 25 Pa. Code § 73.14 (relating to site investigation); 25 Pa. Code § 73.15 (relating to percolation tests); 25 Pa. Code § 73.54 (relating to subsurface sand filters); 25 Pa. Code § 73.161 (relating to general); and 25 Pa. Code § 73.163 (relating to spray fields).